Sample ModesReal-Time Sample
Acquisition Modes 
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs CouplingAC, DC, GND
Inputs Impendance1MΩ±2% ‖ 20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×)
Sample Rate Range1GS/s
Waveform Interpolation(sin x)/x
Record Length2M
SEC/DIV RangeDSO1072E: 4ns/div~2000s/div, in a 2, 4, 8 sequence; DSO1102E: 2ns/div~2000s/div, in a 2, 4, 8 sequence
Sample Rate and Delay Time Accuracy±50ppm over any ≥ 1ms time interval
Scanning Speed RangeDSO1072E: 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 20ns/div to 80μs/div;(-8div×s/div) to 40ms 200μs/div to 40s/div; (-8div×s/div) to 400s; DSO1102E: 2ns/div to10ns/div; (-4div×s/div) to 20ms;
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Volts Range2mV/div to 10V/div at input BNC
BandwidthDSO1072E: 70MHz; DSO1102E: 100MHz; DSO1152E: 150MHz; DSO1202E: 200MHz
Rise Time at BNC( typical)DSO1072E: 5ns; DSO1102E: 3.5ns; DSO1152E: 2.3ns; DSO1202E: 1.8ns
Math+, -, *, /, FFT
FFTWindows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 100V/div to 10mV/div. ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity (Edge Trigger Type)DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; AC: Attenuates signals below 10Hz ; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen;
Set Level to 50%(typical)Operates with input signals ≥50Hz
Video Trigger 
Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field RatesSupports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range100ns ~ 10s
Pulse Width Trigger 
Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Range20ns ~ 10s
Slope Trigger&emsp;