Sample RateReal-Time Sample: 1GS/s Equivalent Sample: 25GS/s
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs CouplingAC, DC, GND
Inpits Impendance1MΩ±2% ‖20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Sample Rate Range500MS/s--1GS/s
Waveform Interpolation(sin x)/x
Record Length40K
SEC/DIV Range2ns/div to 80s/div
Sample Rate and Delay Time Accuracy±50ppm(at over any ≥1ms time interval)
Offset RangeDSO5202P: 2ns/div to 8ns/div; (-8div x s/div) to 20ms;; DSO5102P: 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 80s/div; (-8div x s/div) to 400s
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Position Range2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div to 10V/div , ±50V
BandwidthDSO5202P: 200MHz; DSO5102P: 100MHz; DSO5072P: 70MHz
Rise Time at BNC( typical)DSO5202P: 1.8ns; DSO5102P: 3.5ns; DSO5072P: 5ns
Math+, -, *, /, FFT
FFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, EXT, EXT/5, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity (Edge Trigger Type)DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V
Set Level to 50%(typical)Operates with input signals ≥50Hz
Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V
Holdoff Range100ns ~ 10s
Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Range20ns ~ 10s
Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Over Time ModeRising edge or Falling edge
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope