Sample RateReal-Time Sample: 1GS/s
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWaveform Average, selectable 4,8,16,32,64,128
Inputs CouplingAC, DC, GND
Inputs Impendance1MΩ±2% ‖ 20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Sample Rate Range500MS/s--1GS/s
Waveform Interpolation(sin x)/x
Record Length1M
SEC/DIV RangeMSO5202D: 2ns/div to 40s/div,; MSO5102D: 8ns/div to 40s/div
Sample Rate and Delay Time Accuracy±50ppm ( at over any ≥1ms time interval)
Position RangeMSO5202D: 2ns/div to 8ns/div; (-8div x s/div) to 20ms;; MSO5102D: 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s;
Vertical Resolution8-bit resolution, all channel sampled simultaneously
BandwidthMSO5202D: 200MHz; MSO5102D: 100MHz; MSO5062D: 60MHz
Rise Time at BNC( typical)MSO5202D: 1.8ns; MSO5102D: 3.5ns; MSO5062D: 5.8ns
Offset Range2mV/div to 20mV/div, ±400mV 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V 5V/div to 10V/div, ±50V
Math+, -, *, /, FFT
FFTWindows: Hanning 、 Flatop 、 Rectamgular 、 Bartlett 、 Blackman; 1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, EXT, EXT/5, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity (Edge Trigger Type)DC(CH1,CH2): 1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80KHz; LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V
Set Level to 50%(typical)Operates with input signals ≥50Hz
Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V
Holdoff Range100ns ~ 10s
Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Range20ns ~ 10s
Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Over Time ModeRising edge or Falling edge
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
Manufacturer datasheet
HantekHTK-MSO5000DSERIES

Hantek MSO5000D Series

Mixed Signal Oscilloscope; Bandwidth:60-200MHz; Real Time Sample Rate:1GSa/s;Record Length: 1M; Large (7.0-inch) color display,WVGA(800x480); 16 channels Logic Analyzer,500MSa/s sample rate; Power Trigger mode: edge/pulse width/line sele...

Price on Request
1